M. Böge, A. Streun, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
We present Touschek lifetime calculations based on a refined tracking procedure for determination of the lattice momentum acceptance. The dependency of lifetime on the gap height of insertion devices and on the RF cavity voltage is studied in detail for the reference optics of the SLS storage ring lattice.
Including gas scattering losses we expect 3.5 hrs of total lifetime for 1 nCb bunch charge and 0.1 % coupling. Installation of a 3rdharmonic cavity for bunch lengthening would increase the total lifetime to 8 hrs and thus is recommended.